Friday, September 25, 2015

Dust Wet Scrubber System for Waste Incinerator

Clover supply optional dust wet scrubber system for waste incinerators. the main parts included wet cooling spray scrubber, wet dust filter and fog&waste separator.

This system is valid for mid-large scale waste incinerator, model YD150,YD200,YD300,YD500,YD600. for small scale waste incinerator, supply dry scrubber(filter) chamber.Wet Scrubber System

Orignal From: Dust Wet Scrubber System for Waste Incinerator

Monday, September 21, 2015

Biomedical Waste Incinerator, 10-15 KG 

Biomedical Waste Incinerator, 10-15 kg

Incinerator Introduction
Manufacturer:
Brand:
Type / Model:
Country of Origin:
Description of Function
The Biomedical Waste Incinerator is used for Incineration of each type of Biomedical Waste.
The Disposal of such Biomedical waste is a very important as it is a dangerous wastes for
human life, and It is only possible with a perfect incinerator.
Operational Requirements
It shall be operated by manual and automated mode.
The combustion efficiency (CE) shall be at least 99.00%.
The combustion efficiency is computed as follows:
C.E.= __%CO2______ x 100
%CO2 + %CO
Emission Standards: Lower emission rates are preferred.
Parameters                   Concentration in mg/Nm3 (12% CO2 correction
Max total dust              30mg/m3
Max Sulphur Dioxide      200mg/m3
Max Nitrogen dioxide    400mg/m3
Max Carbon                     100mg/m3
Monoxide
Minimum stack height shall be 30 metres above ground.
Volatile organic compounds in ash shall not be more than 0.01%.
System Configuration
Biomedical Waste Incinerator, complete unit.
Technical Specifications
Incinerator:
It shall be Electrical or Diesel Fired Incinerator or Controlled Air & pyrolytic.
Type of Waste: Biomedical Waste
It shall have burning capacity 10-15 kg/hr.
Fuel: Diesel
Burner: Monoblock fully automatic burners.
Temperature: Primary Chamber 800 ± 50 oC, Secondary Chamber 1050 ± 50 oC.
Type of Waste: Biomedical waste with moisture content up to 85%.
Destruction Efficiency: 99%.
It shall have separate digital display of temperature for both chambers.
It shall have provision for measuring primary & secondary chamber temperatures using external
thermo coupler.
Secondary chamber gas residence time shall be minimum 1 second at 1050 oC.
Primary Chamber:
Type: Static Solid Hearth
Material of Construction: Mild Steel, 5mm thick
Refractory thickness: approx.115mm thick
Material: Refractory bricks confirming to international standard.
Temperature resistance: 1400 oC
Insulation thickness: approx.115mm thick
Material: Insulation bricks confirming to international standard.
Waste Charging: Manual & Automatic waste charging.
Ash Removal: Manual/automatic
Secondary Chamber:
Type : Static Solid Hearth
Material of Construction: Mild Steel, 5mm thick
Refractory thickness: approx.115mm thick
Material: Refractory bricks confirming to international standard.
Temperature resistance: 1400 oC.
Insulation thickness: approx.115mm
Material: Insulation bricks confirming to international standard.
Waste Charging: Manual & Automatic waste charging.
Emergency Stack:
Type: cylindrical, top mounted on venturi ejector.
Material of Construction: Mild Steel, 3mm thick.
Refractory: 75mm thick castable.
Insulation: 25mm thick castable.
Quencher:
Material of construction of outer body: Mild Steel refractory lined from inside.
Shall have water circulation system with centrifugal pump.
It shall have to reduce flue gas temperature before venturi scrubber.
Shall provide pump motor of suitable capacity.
Air Pollution Control Device – Venturi Scrubber
Type: High pressure jet type.
MOC: Stainless steel – 316L.
Temperature at the outlet: 78-80 oC
Scrubbing Media: Water with 5% caustic
Re- Circulation Pump for Venturi Scrubber
Type: Centrifugal
Application: PP/SS
Piping : PPR
Droplet Separator & Re-Circulation Tank (Integral)
Type: Cyclonic
Application: To separate water droplets from flue gases
Material of Construction: Mild Steel Rubber lined 3mm thick
I.D. Fan:
Type: High pressure centrifugal
Material of Construction: Stainless steel 304, impeller and mild steel rubber lined casting
Drive: Bel
Combustion Fan:
Type: Centrifugal
Modulation: Manual damper control
Material of Construction: Mild Steel
Drive: Direct drive
Burners:
No. of burners: 2 Nos. (1 No. in Primary Chamber and 1No. in Secondary Chamber)
Type: Monoblock fully automatic
Fuel: Diesel
Fuel Oil Storage Tank:
Shall provide suitable capacity of oil storage tank.
Material of Construction: Mild steel.
Facility for visual checking of fuel shall be there.
It shall have diesel consumption monitoring system.
It shall come with diesel oil level indicator, piping with valves & N.R. valve.
Control Panel:
Type: Manual & Automated PLC based control panel with printer & recording device.
Material of Construction: CRCA sheet
It shall have digital temperature controller.
Epoxy powder coated washable paint finish.
It shall have audio-visual alarm system.
Chimney of 30 meters Height:
Material of Construction: Mild Steel
It shall be self-supporting type.
Height shall be 30 meters from ground level.
Paint The chimney is painted externally with two coats of heat resistant aluminum paint
Shall provide ladder till the top.
It shall have 3mm thick rubber lining from inside for protection.
It shall come with aviation lamp, lightening arrestor, stack, drain, inspection platform, sampling
port.
Consumption certificate:
The bidder must submit diesel consumption for a daily operation of 6 hours.
Turnkey:
Prices offered shall be inclusive of all civil works, electrical requirements including cabling and
switches required for installation & commissioning of the equipment.
Bidder shall submit detail drawings, design, and layout plan of civil works.
The bidder shall submit the details of BOQ of civil and electrical works.
Accessories, spares and consumables
All standard accessories, consumables and parts required to operate the equipment, including
all standard tools and cleaning and lubrication materials, to be included in the offer. Bidders
must specify the quantity of every item included in their offer (including items not specified
above).
Operating Environment
The system offered shall be designed to store and to operate normally under the conditions of
the purchaser's country. The conditions include Power Supply, Climate, Temperature,
Humidity, etc.
Power supply: 220-240 VAC, 50Hz single phase/400 – 420 VAC, 50Hz three phase as
appropriate fitted with appropriate plug. The power cable must be at least 3 meter in length.
Standards and Safety Requirements
It shall have approval of "Pollution Control Board" of purchaser's country.
All mandatory approvals required for the installation and operation of incinerator shall be done
by the bidder.
Must submit ISO 9001 AND
CE or USFDA approved product certificate.
User Training
Must provide user training (including how to use and maintain the equipment).
Warranty
Comprehensive warranty for 2 years after acceptance.
Maintenance Service during Warranty Period
During the warranty period supplier must ensure preventive maintenance along with
corrective/breakdown maintenance whenever required.
Installation and Commissioning
The bidder must arrange for the equipment to be installed and commissioned by certified or
qualified personnel; any prerequisites for installation to be communicated to the purchaser in
advance, in detail.
Documentation
User (Operating) manual in English.
Service (Technical / Maintenance) manual in English
List of important spare parts and accessories with their part number and costing.
Certificate of calibration and inspection from factory.

Orignal From: Biomedical Waste Incinerator, 10-15 KG 

Friday, September 18, 2015

Small Waste Incinerators 30 and 50kgs

we produce small scale waste incinerators, the capacity from 10kgs,20kgs,30kgs,50kgs,100kgs per hour.

Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime.
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day.
* PLC Control Plane for Intelligent operation.
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.

small waste incinerator

Orignal From: Small Waste Incinerators 30 and 50kgs

Monday, September 14, 2015

Hot sale small waste incinerators 30kgs and 50kgs per hour

1111副本



























































































































Items/Model TS30(PLC) TS50(PLC)
Burn Rate 30 kg/hour 50 kg/hour
Feed Capacity 60kg 100kg
Control Mode PLC PLC
Combustion Chamber 330L 560L
Internal Dimensions 75x75x60cm 100x80x70cm
Secondary Chamber 180L 280L
Smoke Filter Chamber Yes Yes
Feed Mode Manual Manual
Voltage 220V 220V
Power 0.5Kw 0.7Kw
Oil Consumption (kg/hour) 10.2--20 12.1--24
Gas Consumption (m3/hour) 9.8--20 9.9--26.1
Temperature Monitor Yes Yes
Temperature Protection Yes Yes
Oil Tank 100L 100L
Feed Door 55x50cm 70x55cm
Chimney 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃--1000℃ 800℃--1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec.
Gross Weight 3000kg 4500kg
External Dimensions 175x120x140cm 230x130x155cm


Orignal From: Hot sale small waste incinerators 30kgs and 50kgs per hour

Small Scale Medical Waste Incinerators

Clover Incinerator supply medical waste incinerators with capacity 10kgs per hour to 500kgs per hour. The incinerator with dual/double combustion chamber and dry filter chamber, two fuel burner from Italy manufactured, hot sale model for small scale waste output, the capacity is 30kgs per hour and 50kgs per hour.

We are famous small scale incinerator manufacturer and brand, dispatch incinerator products and best services with lower price for customer all around the world.

Contact with us now:

Tel: 0086-25-8461 0201

Email: sales@clover-incinerator.com

Facebook ID: hiclover

TS30 Waste Incinerator

 

Orignal From: Small Scale Medical Waste Incinerators

Sunday, September 13, 2015

Waste Incinerator vs Pet Cremator

a.) incinerator for waste. VS cremator for animalsanimal-cremation


b.) incineration to be ash and clean it. VS cremation and collect ash into pet cremation urns.pet-cremation-urns


c.) waste stack disorderly.VS pet in chamber individual.


d.) waste material complicated. VS pet is body.


e.) waste incineration is public affairs. VS pet cremation is personal business more.265_00066_23SEPT.jpg


f.) waste incinerator with small-large scale capacity. VS pet cremation with regual pet size or weight


g.) waste incinerator feeding door small or big. VS pet cremator feeding door match with pet size


h.) waste material with or without fat. VS pet body with fat.cremation-ash


i.) waste incinerator with or without exchange feeding door. VS pet cremator better with exchange feeding door.pet-cremation-in-incinerator-chamber



Orignal From: Waste Incinerator vs Pet Cremator

Tuesday, September 1, 2015

Waste Incinerator vs Pet Cremator

Incinerator means same with cremator if you said incineration, but there is some difference.incinerator.info


a.) incinerator for waste. VS cremator for animals



b.) incineration to be ash and clean it. VS cremation and collect ash into pet cremation urns.


  pet cremation urnscremation ash



c.) waste stack disorderly.VS pet in chamber individual.


d.) waste material complicated. VS pet is body.


pet cremation in incinerator chamber


e.) waste incineration is public affairs. VS pet cremation is personal business more.


animal cremation


f.) waste incinerator with small-large scale capacity. VS pet cremation with regual pet size or weight


g.) waste incinerator feeding door small or big. VS pet cremator feeding door match with pet size


h.) waste material with or without fat. VS pet body with fat.


i.) waste incinerator with or without exchange feeding door. VS pet cremator better with exchange feeding door.


animal crematory



Orignal From: Waste Incinerator vs Pet Cremator